NL EN

Beta for the first users · engine 0.4.0 · Studio 0.4.0

Noise studies you can defend

Attenix calculates road traffic, railways and industry exactly by the Dutch Omgevingsregeling, the RMG 2012 and CNOSSOS-EU. For every number it records how it was reached, down to the clause of the regulation.

Download Studio 0.4.0

Windows 10 or 11 (64-bit) · direct, no request needed

Attenix Studio with a study of Rotterdam open: the Layers panel on the left with its toolbar and the layers Results, Receivers, Screens, Roads, Buildings and the background map; in the middle the map of the Kleinpolderplein junction with the receivers coloured by Lday; beside the map the legend of the general colour scale of DIN 45682, above it the study bar reading Up to date · run of 1 October 2026, 07:22, the runs in the Runs panel on the right; the Receiver results table under the map, and Trial period: 30 days left in the status bar
A study of 182 roads, 33 275 buildings and 428 receivers around the Kleinpolderplein junction in Rotterdam, calculated with Bijlage IVe (2024): its receivers coloured by Lday on the general scale of DIN 45682, with the Receiver results table below. Background map: BRT, © Kadaster, CC BY 4.0; Studio 0.3.5, 2026-11-11.
Noise map 2026 Adopted by 2027-06-30

The 2026 noise map

The 2026 strategic noise map (geluidbelastingkaart) must be adopted by . Attenix takes the buildings, ground and terrain from 3D Geluid and the roads from a traffic model. It calculates by CNOSSOS-EU with the Dutch Bijlage XXXIII, counts the residents per class within the municipal boundary and assembles the delivery to RIVM. The export and its validation are checked against the documented Cvgg checks of the 2026 manuals.

The noise map step by step

Your work Road · rail · industry

What you do with it

Everything below is in the released engine 0.4.0 and Studio 0.4.0.

  • Road traffic

    Bijlage IVe in its texts of 2024 and 2026-07, SRM II of the RMG 2012 and CNOSSOS-EU with Bijlage XXXIII. You take the roads with their traffic from a traffic model, a count or the noise register.

    More on road traffic

  • Railway and tram

    Bijlage IVf in both texts, with steel bridges and the standing trains by Bijlage IVh, and CNOSSOS-EU rail with Bijlage XXXIII. Tracks with their train traffic come from the noise register or from a file of your own.

    More on railways

  • Industry

    Bijlage IVh, model II.8 and method I, with LAmax, and CNOSSOS-EU industry. You draw point, line and area sources with directivity in Studio, or take them from an input file of the industry Rekenhart.

    More on industry

  • The noise map

    From 3D Geluid and a traffic model to the delivery to RIVM: facade points, receiver grid and contours, and the dwellings and residents per class.

    More on the noise map

  • Assessment and measures

    The level beside its limit, the sources that set the level at a group of receivers, and the effect of each screen. The engine calculates other screen heights exactly.

    More on sources and screens

  • The calculation engine on the command line

    The command-line tool attenix is the calculation engine of Attenix, its rekenhart, as the Dutch field calls the program that calculates a level by the prescribed method. Studio calculates with the same engine; the tool also runs without Studio, on Windows and Linux. It is not RIVM’s program Rekenhart geluid.

    More on the command-line tool

Traceability Reproducibility

Results that hold up in a review

A level you calculate ends up in a permit, a zoning plan or a noise map, and somebody will ask how it was made. Attenix is built so that the answer is written down before the question is asked.

Every run writes a manifest with the method edition, the implementation version, every setting and the digest of the input. Where a regulation is unclear, the reading Attenix chose is a numbered entry in a register. The same input gives the same number to the bit, on every supported platform.

What a reviewer receives

Receiver 20 selected in the Receiver results table of Attenix Studio; the Properties panel shows its position and height and, under Results of the run of 11 November 2026, 11:06, its Lday of 65.1 dB(A), Levening, Lnight and Lden at 8.0 m, with the spectrum of its Lday per octave band below
Study kleinpolderplein-2km: a receiver’s levels and the spectrum of its Lday. Background map: BRT, © Kadaster, CC BY 4.0; Studio 0.3.5, 2026-11-11.
Evidence Without the source code

Check it yourself

56 of 56
ISO/TR 17534-4 test cases for CNOSSOS-EU passed; the run holds for engine 0.4.0
3 source types
road traffic, rail traffic and industry, each compared with RIVM’s Rekenhart programs
2 editions
of Bijlage IVe side by side, the text of 2024 and that of July 2026: an earlier study can still be recalculated with the old one
  • Compared with the Rekenhart: Attenix is compared with RIVM’s Rekenhart programs for road, rail and industry, on test scenes and on real neighbourhoods in Amersfoort and Nijmegen. Every difference above 0,1 dB is classified, and the defects found in Attenix this way are fixed. This is a comparison, not a conformity claim, and it implies no endorsement by RIVM.
  • ISO/TR 17534-4: for every release Attenix calculates the ISO/TR 17534-4 test cases for CNOSSOS-EU propagation. The cases themselves are not public; the outcome of every run is recorded. How the results are checked
  • Recalculate it yourself: the noise-map example is made from open data only: 3D Geluid, the Provincie Utrecht’s traffic volumes, the BAG and CBS Wijken en buurten. The example and its data
  • The developer: the team behind Acrotron has extensive experience supporting the US government with its noise modelling software. Acrotron is listed as a developer in the public technical manuals of FAA AEDT. Who makes Attenix
Released As of 2026-11-22

Where Attenix stands

Engine 0.4.0 and Studio 0.4.0, of , are beta releases for the first users. A release for general use, the terms and the prices are not yet announced.

Attenix is still in beta. A lot can still change between releases: the functions, the interface, the file formats and also the results, as the implementation of a method is refined. We would like to hear from users what works, what does not and what is missing: info@acrotron.com.

What each release brought and what is in development

Questions

Frequently asked questions

Can I use it for a study I hand in today?

Engine 0.4.0 and Studio 0.4.0 are beta releases for the first users. Use them to try Attenix on your own studies and compare it with the program you use now, and tell us what you find. A release for general use is not yet announced.

Can I bring my existing models?

A study is a GeoPackage, which GIS software opens and writes. Models in the QSI data interface of DIN/TS 8998-1 are imported with their receivers, buildings, screens, terrain and ground areas; sources come as geometry only, since QSI has no supplement for these methods. The command-line tool makes a study from an input file of the Rekenhart geluid, for road or rail traffic, or of the industry Rekenhart, and from the IMGeluid files of the noise register; Getting started shows how.

Who makes Attenix?

Acrotron, since 2017. The team behind Acrotron has extensive experience supporting the US government with its noise modelling software, including FAA AEDT and FHWA TNM. For management sums up what that means, and what happens to your data and calculations.

What does it cost?

Licensing and prices are not yet announced.

All questions

Contact Acrotron · Zeist

Your contact person is in Zeist

Attenix is developed in Zeist, in the Netherlands, which is also where your contact person is. We are glad to show Attenix on your own data, help you with a trial and discuss the methods and the readings in the registers.

Tell us which methods you calculate and how large your studies are, so that we know what matters to you.

Write to info@acrotron.com

What you can write to us about

Further

Read further

  • Getting started

    From the example that comes with Studio, a Rekenhart file or open data to a first calculated study.

    Getting started

  • Videos

    A three-minute overview and eleven short videos, from building a study to delivering the noise map and calculating on several computers.

    All videos

  • For management

    A summary to pass on: who makes Attenix, what happens to your data and why the results stand up to a review.

    For management