NL EN

For reviewers

How a result of Attenix is followed back to the clause of the regulation without the source code: the questions a reviewer asks, the written answers and the documents they are read in, one equation followed through those documents, and how the results are checked.

Who it is for Engineers · reviewers Decision makers

A level that nobody can trace has to be checked again

A calculated noise level ends up in a permit, a zoning plan or a noise map. Somebody then has to trust it: the engineer who signs the study, the reviewer at the competent authority who assesses it, and whoever decides on it. The questions they ask are the same every time. Which text of the regulation was used, and which edition? How was a formula read where the text is unclear or contains an error? Where does the calculation depart from the text? And will the same input give the same number next year?

When those answers are not written down, the review falls back on the reviewer’s own experience, on recalculation, or on trust. Attenix is built so that each of those questions has a written answer that a reviewer can follow from the result back to the clause.

  • For the engineer

    The method edition, the path finder and every version are named in each result. Problems in the input are reported before a long calculation starts, and an edit is recalculated without redoing the whole study.

  • For the reviewer

    A traceability matrix lists the clause behind each formula; each reading of an unclear text is a numbered entry with the question, the options and the reason; each departure from the text is listed in a deviation register. None of it needs access to the source code.

  • For the decision maker

    Results are reproducible to the bit, the checks run on every change, and this site says plainly what is released, what is still in development and what Attenix does not cover.

Reference register Interpretation register Deviation register Manifest

Four questions, four written answers

Attenix keeps the texts it implements, the readings it chose and the evidence together with its code, and generates its documents from them, so that the documents cannot drift from what the code does. Each answer below names the document in which a reviewer reads it.

  • Which text: every legal text and standard the engine implements has a Ref ID in a reference register, such as NL-OMGR-IVE for Bijlage IVe. Where reuse is allowed, the exact consolidated text is stored with a SHA-256 checksum that is checked automatically. A new version of a text goes next to the old one, so an older method edition stays tied to the text it implements. ISO standards and other copyrighted sources are referenced, never copied. Shown in the QA documentation of each module edition, which lists the dated references with their version and licence.
  • Which formula: every formula in the implementation carries the Ref ID and the clause, equation or table it implements, and a check fails when a formula has no citation or cites an unknown source. Dutch legislation publishes its formulas as images, so each formula is transcribed once, and the implementation, the tests and the independent reference implementation all use that one checked reading. Shown in the traceability matrix of the QA documentation, generated from those citations, and in the formula reference, which sets each transcribed equation next to the entries that concern it.
  • Which reading: where a text is ambiguous, contains an evident error or leaves a choice open, the choice is a numbered entry in an interpretation register, with the clause, the question, the options considered, the choice and its reason. Changing a choice changes results, so it needs a new implementation version of the module; the old version keeps the old choice. Shown in the interpretation register of each module edition and in the deviation register, which lists every entry that corrects, extends or limits the text and counts the ambiguities.
  • Same input, same number: results are identical to the bit on every supported platform, independent of threads, tiles and hardware, and an incremental recalculation gives the same results as a full one. Shown in the manifest that every calculation writes, with the module edition, implementation version, parts and rule set it used; the same manifest replays the calculation.
Deliverables ISO 17534-1 Source code not public

What reviewers and customers get

The source code of Attenix is not public. What makes a result traceable is a set of documents that the engine generates from its code, its specifications and its registers, and that a check compares with them on every change. Some come with every calculation. The others form a QA package per module edition, kept unchanged per product release: it comes with a licence, and reviewers at competent authorities who assess a study calculated with Attenix can request it.

With every calculation

  • Calculation manifest: written next to the results. It records the engine version; every module with its edition, implementation version, parts, signer and data tables; the path-finder rule set; the digest of the input and how it was imported; every parameter and setting; whether the run was full or incremental; and warnings, such as a calculation with a proposal that is not the text in force. Its SHA-256 digest identifies the calculation. Replaying the manifest reproduces the result with exactly the recorded versions, or refuses when one of them is not installed.
  • Trace: when tracing is switched on for chosen receivers, every intermediate value of every path, meteorological condition and octave band, under the symbols of the method. The results are the same to the bit with and without it.

Per module edition: the QA package

  • QA documentation: one document per module edition, in the sections that ISO 17534-1 (§5.1.1, §5.1.2, §5.2.2 and §6) asks of calculation software: the method and its dated references, how completely each calculation step is implemented, the general strategies, the reference configuration and the settings that can or cannot change results, the interpretations, the traceability matrix, the tools to check a calculation, uncertainty determination, the validation cases with their largest deviation, and how changes that can influence results are listed. The documents of a product release are kept unchanged.
  • Validation cases: the cases built from the public texts, each with its input, its expected results and their tolerances, as ISO 17534-1 (§4.5.2) describes them, so that a reviewer can calculate them in another program or by hand and compare. Together with the manifest, which reproduces any result with the recorded versions, the evidence does not have to be taken on trust.
  • Declaration of conformity: in the form of ISO 17534-1 (§6, Annex B), with the test-case requirements and the grade of implementation of each calculation step. It is Acrotron’s own declaration, not a certification, and it is generated together with test cases that are under licence and are not published.
  • Method description: per module, how each edition calculates, in prose, with the differences between editions; each section cites the requirements and interpretation entries it describes.
  • Formula reference: per module edition, every equation, table and figure the implementation cites, as transcribed, with its interpretation entries and their kind, and the trace quantities that record its terms.
  • Interpretation register: per module edition and per path finder, every reading of an unclear text: its id, source and clause, kind (ambiguity, correction, extension or limitation), the question, the options considered, the choice, the reason, and the implementation version since which it applies.
  • Deviation register: every correction, extension and limitation of every module edition, every calculation step implemented only in part or not at all, and the number of ambiguities per register.
  • Change log: between two product releases, every change that can influence results: parts, rule set, interpretations, parameters, maximum distance and the stored reference results.

The documents never contain text or data of a privately licensed source, such as an ISO document: such sources are cited by Ref ID and clause only.

With the software

  • Software bill of materials: every engine package and every installation of Attenix Studio contains an SBOM in CycloneDX, the standard format that IT departments and security scanners read. It lists every component with its exact version, its licence and a hash of its files, including the third-party code inside the engine, the libraries inside Studio’s map renderer and coordinate library, and the .NET runtime Studio needs. The same release gives the same SBOM. In Studio, Help ▸ About links to it.
NL-OMGR-IVE-2024 §2.10, eq. 2.18a INT-nl-omgr-ive@2024-020

One clause, followed through the documents

This is what those answers look like for one equation: the calculation height of a source behind a screen in the 2024 text of Bijlage IVe, where the printed text has two problems. The example is real. The entry and the table rows below are taken, shortened, from the documents of nl-omgr-ive@2024 that a reviewer receives.

  1. The source text

    NL-OMGR-IVE-2024 §2.10, eq. 2.18a, as printed

    z′_B = z_B + Δz_B x = 0,75 (z_B − z_T + 0,25) Δz_B = 0,65 if x < 0 Δz_B = 0,4625 − 0,75 (z_B − z_T) if 0 < x < 0,65 Δz_B = 0 if x > 0

    The printed text has two problems: the second and third cases overlap for 0 < x < 0,65, and the sign of the first line differs from the text before it and the text after it.

  2. The interpretation entry

    Interpretation register of nl-omgr-ive@2024

    INT-nl-omgr-ive@2024-020 — Overlapping cases and sign of eq. 2.18a (2024 text)

    Ref
    NL-OMGR-IVE-2024
    Clause
    2.10, eq. 2.18a
    Kind
    Correction. The printed text is read as an error, and the entry names the texts that support the corrected reading.
    Question
    For 0 < x < 0,65 both the second and the third case apply: which one? And the 2024 text prints z′_B = z_B + Δz_B, where the text before it (NL-RMG2012-III) and the amended text of 2026-07-01 have z′_B = z_B − Δz_B: which sign?
    Options
    Cases: the second case (a continuous Δz_B) or the third (Δz_B = 0 for all x > 0). Sign: + as printed, or − as in the texts before and after.
    Choice
    The second case for 0 < x < 0,65, the third for x ≥ 0,65; z′_B = z_B − Δz_B, the printed “+” read as a printing error.
    Rationale
    Only the second case makes Δz_B continuous, and the amendment of 2026-07-01 sets the bound of the third case to 0,65. The texts before and after have −, and RIVM’s calculation program for the 2024 text computes with −. The explanatory notes of the amendment call both a writing error.
    Since
    Implementation version 1.0.0
  3. The registers and the traceability matrix

    Deviation register; QA documentation of nl-omgr-ive@2024, section 8

    Because the entry corrects the text, the deviation register lists it with the other departures from the texts:

    Deviation register, row for eq. 2.18a
    SourceKindSubjectEntry
    NL-OMGR-IVE-2024 §2.10, eq. 2.18a correction Overlapping cases and sign of eq. 2.18a (2024 text) INT-nl-omgr-ive@2024-020

    The implementation of the screening part cites the clause, the equation and the entry. The traceability matrix of the QA documentation is generated from those citations, so it shows which code element implements eq. 2.18a and which entries it follows:

    Traceability matrix, rows for eq. 2.18a in the edition 2024
    Ref IDClauseEquationCode elementInterpretation
    NL-OMGR-IVE-2024 2.10 eq. 2.18a Screening2024 INT-nl-omgr-ive@2024-007
    NL-OMGR-IVE-2024 2.10 eq. 2.18a Screening2024 INT-nl-omgr-ive@2024-020

    A check fails when the implementation cites an entry that does not exist, when an entry lacks one of its fields, or when a document differs from the one generated from the current code. Entry 007 assigns the boundary values x = 0 and x = 0,65 to a case, since the printed conditions are strict.

  4. The result

    Manifest and trace of a calculation with nl-omgr-ive@2024

    Module
    nl-omgr-ive@2024, implementation version 1.0.0
    Part
    screening 2024/1.0.0
    Path finder
    nl-sector@1.0.0

    A changed reading needs a new implementation version, so the versions in the manifest say which reading of eq. 2.18a a result rests on. With tracing switched on, the calculation height z′_B of every screened path is recorded under its symbol, and a reviewer can check it by hand for a receiver. The QA documentation and the method description show the same correction, set apart from the source text.

Validation Comparison Reproducibility

How the results are checked

Traceability says what the engine is meant to calculate; the checks show that it does. Most checks run automatically on every change, some also weekly with many more cases; the ones that need licensed material or another program run locally.

  • Analytical reference cases: validation cases for both editions of Bijlage IVe, of Bijlage IVf and of Bijlage IVh with its method I, for Standaardrekenmethode 2 of the RMG 2012 and for the CNOSSOS-EU modules for propagation, road traffic, railway traffic and industry with their Dutch adaptations, built from the public texts and calculated by an independent reference implementation from the same transcriptions. For CNOSSOS-EU they cover, among others, mixed ground, one and two thin screens, a building as a thick obstacle, reflections of the first and second order, all five vehicle categories of road traffic, and the bridges, joints and curves of railway tracks. The QA documentation lists each case with its largest deviation.
  • ISO/TR 17534-4 test cases: the test cases for CNOSSOS-EU propagation pass with the edition 2015-996 that they test; edition 2021-1226 passes every case the amendment leaves unchanged, and its amended readings are checked against analytical cases. The cases come from a document under a single-user licence, so they run from a private corpus and are not published. Only the outcome of each run is recorded. In the run for the release 0.1.0, on 2026-10-14, all 56 cases (TC01 to TC28, with and without lateral diffraction) passed with edition 2015-996, again in the run of 2026-10-24 in development, and in the run for the release 0.2.0, on 2026-11-03. In the run for the release 0.3.0, on 2026-11-05, all 56 cases passed again; the releases 0.3.1, 0.3.2 and 0.3.4 change nothing these cases calculate, so that run holds for them too. The release 0.3.5 changes the engine that calculates every case, so it had a run of its own: on 2026-11-11 all 56 cases passed again with edition 2015-996, and edition 2021-1226 passed the cases the amendment leaves unchanged. The release 0.3.6 changes only the contours and the SQLite library that reads and writes GeoPackages, nothing these cases calculate, so the run of 0.3.5 holds for it too. For the release 0.3.7 the run was repeated: on 2026-11-12 all 56 cases passed again with edition 2015-996, and edition 2021-1226 passed again. The release 0.3.8 adds analyses of results, stores the calculation settings of a Rekenhart import and corrects a value of Bijlage XXXIII, which these cases do not calculate; it changes no path, value or level that they do calculate, so the run of 2026-11-12 holds for it too. For the release 0.4.0 the run was repeated: on 2026-11-20 all 56 cases passed again with edition 2015-996, and edition 2021-1226 passed again. Each release needs such a recorded run.
  • Comparison with the Rekenhart geluid: nl-omgr-ive@2024 and nl-omgr-ivf@2024 are compared with RIVM’s calculation program for road and rail traffic, which follows the 2024 texts: for road traffic on scenes that include a cut, a fill, a viaduct, earth berms, several screens and a residential district, and on two real-world scenes built from open data (road centre lines, buildings and ground areas), in Amersfoort with 366 receivers and in Nijmegen with 412; for rail traffic on the analytical cases of Bijlage IVf. Every difference above 0,1 dB is classified as a defect in Attenix, a choice of the program or an ambiguity of the text, and the defects in Attenix that the comparisons found are fixed, some of them only in the release 0.2.0. For the release 0.3.7 the comparisons of road, rail and industry were run again on 2026-11-12, with the same outcomes as on 2026-11-11. These comparisons hold for the release 0.3.8 too: it changes nothing they calculate, and the Rekenhart files are read in the same way. The release 0.4.0 changes the levels of Bijlage IVe, IVf and SRM II where source point and receiver differ in height; for that release the comparisons of road, rail and industry were run again on 2026-11-20, with RIVM’s Rekenhart programs of 13 November 2026, and every difference above 0,1 dB is classified. This is a comparison with another program, not a conformity claim, and it does not imply endorsement by RIVM.
  • Comparison with the industry Rekenhart: nl-omgr-ivh@2024 is compared in the same way with RIVM’s calculation program for industrial noise, on the analytical cases of Bijlage IVh and on two plant scenes with halls, a tank, a screen, open installations and five sources. Every difference is classified; one defect in Attenix, found after the release 0.1.0 by the scenario families below, is fixed in the release 0.2.0. This is not a conformity claim either.
  • Scenario families: since the release 0.1.0, 174 families of scenes, for every method and its Dutch adaptations, vary one element at a time (the length and shape of a source line, the traffic, the buildings, the ground, the distance and height of the receiver) and check relations that must hold, with stated tolerances: a doubled flow adds 10 lg 2, a longer line is never quieter, moving the scene changes nothing. The families of the Dutch methods are also calculated by the Rekenhart programs.
  • Property, fuzz and mutation tests: also since the release, every method is checked on random scenes against changes that must leave its levels as they are, the importers are given damaged input, and mutation tests report changes to the code that no test notices.
  • Bit-identical results: every change is built and tested on Windows x64, Linux x64 and Linux ARM64, in both SIMD modes, against frozen golden outputs.
Video, 1 min 39 s, with on-screen explanations and quiet background music, in the English interface. Converting and calculating an input file of the Rekenhart geluid of our own, the calculation manifest with the versions of the modules, and where the comparison with the Rekenhart geluid is. Recorded with Studio 0.4.0 on 2026-11-23; background map: BRT, © Kadaster, CC BY 4.0. All videos. Text of the video.